Hydraulic injection injury

Date published: 30 September 2014

Introduction

The purpose of this safety alert is to raise awareness of the risks from hydraulic injection injury.

Initial findings from an HSE (GB) investigation has found that whilst a maintenance fitter was using a hand powered grease gun to tension the track of a piling rig, the nipple connecting the grease gun to the track mechanism detached, permitting the grease (under significant stored energy) to release, injecting the fitter.

Background

Hydraulic injection injury occurs when the outer layer of skin is broken by a jet of fluid under pressure.

Although serious reported instances of hydraulic injection have occurred at pressures over 100 bar (1450 psi), anecdotal evidence suggests hydraulic injection injury may occur at pressures as low as 7 bar (101.5psi).

Injection injury often results from a failure of a component in the mechanical system. This can result in the equipment remaining in use and pressurised whilst leaking fluid.

A person may come in to contact with a fluid jet while using equipment or when carrying out inspection and/or maintenance prompted by a reduction in performance of the equipment.

This can cause harm in two ways:

  • the mechanical pressurised penetration and subsequent trauma to the surrounding and underlying tissue
  • the toxicity of the fluid injected into the injured party

The severity of the injury varies according to the following:

  • pressure
  • proximity
  • jet size

Following any injection injury, prompt action is essential to save the injured persons limb, or even life.

Without medical treatment, after four – six hours the victim may experience intense throbbing pain that is unresponsive to pain medication.

Without proper care injection injuries can lead to amputation of affected parts.

Action required

Anyone maintaining mechanical plant should inspect the integrity and security of grease nipples and pipe work adapters used as part of track tensioning systems. This should take place at routine service intervals and before attempting to carry out vehicle track tensioning at any time.

Where replacement or maintenance takes place on a pressurised system, fittings should be matched and compatible as per the original equipment manufacturers specification.

Verification of such replacement should be regarded as a pressure test and appropriate precautions taken.

Personnel should be familiar with the steps to take, if injection injury occurs, particularly the need to seek immediate professional medical treatment.

More information

Awareness to a previous reported incident is available at: safequarry.com

Share this alert

Please pass this information to anyone involved in hydraulics engineering or general maintenance technicians.

Share this page